This standard is issued under the fixed designation C; the number Conversion and rounding given in Standard IEEE/ASTM SI. The intention of this article is to clarify the specifications listed in ASTM C, Standard Specification for Mixing Rooms, Moist Cabinets, Moist. ASTM C Mixing Rooms, Moist Cabinets, Moist Rooms, and Water Storage. Tanks Used in the Testing of Hydraulic Cements and Concretes.

Author: Mitaxe Dogor
Country: Liechtenstein
Language: English (Spanish)
Genre: Video
Published (Last): 23 October 2009
Pages: 159
PDF File Size: 4.79 Mb
ePub File Size: 13.40 Mb
ISBN: 970-6-84334-939-7
Downloads: 1314
Price: Free* [*Free Regsitration Required]
Uploader: Kagagrel

Importance The importance of having a properly functioning curing facility cannot be overstated.

Some of the most common errors include: In both cases, extreme care must be taken to prevent water astn dripping onto the stored specimens, since lime can leach out and lower the strength.

If the calcium hydroxide is disappearing when stirred, the water is not saturated. It is best to have them inside and against an interior wall.

High temperatures can lead to falsely high strength. Each laboratory will need to consider the unique requirements of their testing needs when designing and maintaining asrm curing facility. Tariq – Your QA will be contacting you about this question shortly. The Cure for The Cure: Requirements for Moist Rooms If your lab tests a lot of samples or tests a variety of materials, a curing room might be the best choice for you.

ASTM C Standard

Thank you for the comment! Alternatively, you can connect your tanks with tubing, basically creating one large tank see Figure 2.

The benefit of a chart recorder is that the information is readily available and in full view at all times, and labs that use these tend not to get written up for not evaluating the weekly temperature data. Tanks compliant with C will also meet the requirements of C Curing rooms range in size, and it is recommended that labs install shelving in a configuration convenient to the size and shape of the room. Saturated C cure tanks have a considerable amount of excess calcium hydroxide sitting in the bottom of the tank.

If you choose this option, you must make sure that there is a means of evenly circulating the curing solution throughout all of the tanks. The water should be saturated. This will significantly help maintain the temperature and humidity requirements. Most labs that choose this method use a fish pond circulator.

TOP 10 Related  VARIOMATIC TRANSMISSION PDF

The requirements for this soaking period are temperature and the use of calcium hydroxide. Take the time to install insulation, piping, replaceable misters, heating and cooling units, circulators, and temperature recording devices as applicable.

Thanks for reaching out to us. The first option is to equip each tank with a temperature recorder that is monitored weekly. The system shall be equipped with a temperature recorder and a reference temperature measuring device that are to be placed practically near to each other. You’ve already submitted a review for this item. Your comment must be approved first. Subscribe to new comments. While it is nice to be able to have all of the temperature records on a computer, CCRL inspectors report that laboratories using these data loggers often forget to download and evaluate the data.

Learn how to be an AASHTO lab 24/7

According to an informal poll of CCRL inspectors, the number of laboratories with curing tanks versus curing rooms is about evenly split. The easiest way to determine this is to add calcium hydroxide to the water and then stir the water.

A common problem with misters is that ast, tend to clog. Whether you have multiple tanks sstm just one tank, you must perform routine maintenance. Comment cannot be empty.

The size of your room will depend on how much space is available in your lab and how many samples you plan to store. Tanks also require additional documentation. Tanks are available from typical laboratory suppliers, but also from farm supplies, as they can also be d511 as food and water troughs for animals. There are two options to fulfill this requirement. This article is not c51 exhaustive account for all mix designs, regional specifications, or capabilities of each laboratory.

If you decide to go this route, you will need to have at least one calibrated chart recorder or digital recorder per tank see Figure 1.

TOP 10 Related  DISCOVERING HAPPINESS BY DENNIS WHOLEY PDF

Depending on the type of material you are working with, you should refer to the applicable specification or standard to determine whether you need to maintain tanks or a curing room, or even a tank within a curing room.

In order to maintain an extremely humid environment, you must have a good water supply and humidifying equipment, and the temperature must be maintained at If you have to install a moist room against an exterior wall, try to give at least 6 inches of dead air space. Maintaining two sets of working spray nozzles will be less time consuming than continuously repairing dripping nozzles, or suffering the consequences of improperly cured materials.

Aatm installing the c5111 room and insulating it, labs need to install misters onto asmt lines spaced throughout the room. It is highly recommended that laboratories institute a program in which the spray nozzles are switched out with a second set that has been soaking in a mild acid such as vinegar to slow the clogging process.

Air in moist aatm or moist room shall be saturated with moisture in order to provide specified storage conditions and air temperature shall be controlled with provisions made for heating, cooling, or both. Please type the code above.

ASTM does not give zstm warranty express or implied or make any representation that the contents of this abstract are accurate, complete or up to date. They both seem to be equally popular. Common Errors CCRL inspectors write many findings in their reports on curing facilities and associated records. Moist cabinets and moist rooms shall be constructed of durable materials with tight-fitting doors or windows for all openings.

It is informational only and not an official part of the standard; the full text asstm the standard itself must be referred to for its use and application. You may use either a chart recorder or a digital recorder. At least every 24 months, you must clean and refill each tank with calcium hydroxide to saturation.